GCU : Gas Control Unit
Specifications
Electrical Specifications :
GCU Current Consumption: 30 mA average (The servo current consumption may be higher and will vary with different servos.)
4.8V to 12V (any type of battery)
Polarity protection on Power input
Boiler Pressure Setting Range : 0 – 6.3Bar
Items Supplied :
GCU control box
Boiler pressure sensor (Threaded ME ¼ by 40)
Red Alert LED
Blue Gas ON LED
Large LED’s - System Status/Fault Indicators visible from the pond side
Blue LED - System Status Indicator for Gas
LED Solid ON : Gas ON - Gas Servo open, gas burner heating the boiler
LED Blinking : Gas servo partially open – close to pre-set pressure
LED OFF : Gas on Pilot Light Setting – Boiler at set pressure
Red LED – System Status Indicator / Alert
Red LED Blinking : Alert
Low Input voltage
Red LED Solid ON : Safety-critical Alarm - emergency gas cut-off :
Critically Low Input Voltage – GCU cuts off the gas supply.
Pressure sensor connection failure - Pressure sensor not connected properly (this is a dangerous situation), the controller will no longer be able to maintain the boiler pressure – GCU cuts off the gas supply.
NB The inclusion of a radio controlled on/off switch into the boiler pressure sensor line enables the user to remotely effect an emergency gas cut off.