WCU : Water Control Unit

Specifications

Items Supplied

  • Boiler water gauge level sensor for 5mm diameter sight glass (other sizes available upon request).

  • Red Alert LED

Additional Items Required 

On/Off switch

Cold tank – Boiler feedwater tank - low water level sensor

Feedwater control valve (90° closed to fully open, lever valve).

Electric Feed Pump

Electrical Specifications :

  • 4.8V to 12V (any type of battery)

  • Polarity protection on Power input

 Large Red LED - System Status/Fault Indicators visible from the pond side

LED Blinking : Alert

  • Low input voltage

  • Low water level in the boiler feedwater tank

  • Boiler water level – demand for water not yet satisfied

LED Solid ON : Safety-critical Alarm System

  • Critically low input voltage 

  • Boiler water level gauge sensor temp (green wire) connection fail - sensor not connected properly (this is a dangerous situation), the WCU will not be able to maintain the boiler water level.

  • Boiler water level not achieved. Pump not able to supply enough cold water into the boiler to reach the preset water level within one minute.

  • Low cold/feedwater tank water level and low boiler water level